BPDQD - SN60 (SN60PB40) WRAP 2 SOLDER
- MSDS: BPDQD
- Manufacturer: MULTICORE SOLDERS INC
- Product Name: SN60 (SN60PB40) WRAP 2 SOLDER
- National Stock Number: 3439-00N030101
Product Identification
Product ID:SN60 (SN60PB40) WRAP 2 SOLDER
MSDS Date:08/12/1991
FSC:3439
NIIN:00N030101
MSDS Number: BPDQD
Responsible Party
RICHARDSON, TX 75081
US
Emergency Phone: 214-238-1224
Info Phone: 214-238-1224
Preparer: ROBERT L. GILBERT
Cage: 03051
Contractor
Telephone: 214-238-1224
Cage: 03051
Ingredients
LEAD
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 35-40%
OSHA PEL 0.05 MG/M3
ACGIH TLV: 0.15 MG/M3 DUST
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
TIN
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: 55-60%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3
ROSIN ACID; (ROSIN CONTAINING ING 4 & 5)
CAS: 8050-09-7
Fraction By Weight: 1-3%
FORMALDEHYDE
CAS: 50-00-0
RTECS: LP8925000
OSHA PEL SEE 1910.1048
ACGIH TLV: C 0.3 PPM; A2; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
TURPENTINE
CAS: 8006-64-2
RTECS: YO8400000
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE:WEAKNESS, VOMIT, LOSS OF
APPETITE, CONVULSIONS, STUPOR & POSS COMA. CHRONIC:WEAKNESS,
INSOMNIA, HYPERTENION, SLIGHT IRRIT OF EYES, HDCH, POSS PARALYSIS.
CHRONIC OVEREXP TO LEAD MAY RSLT IN DAM T O BLOODFORMING, NERVS,
URINARY & REPRODSYS.FORMALDEHYDE FORMED DURING DECOMP OF ROSIN FLUX
IS LISTED AS (SUPP DATA)
Explanation of Carcinogenicity:LEAD: GROUP 2B (IARC). FORMALDEHYDE:
ANTICIPATED TO BE A CARCINOGEN (NTP), 2A (IARC), OSHA REGULATED.
Effects of Overexposure:DUST, VAPOR AND/OR FUMES MAY BE IRRITATING TO
SKIN, EYES, AND RESPIRATORY SYSTEM.
Medical Cond Aggravated by Exposure:NOTE TO MD:LEAD AND ITS INORGANIC
COMPOUNDS ARE NEUROTOXINS WHICH MAY PRODUCE NEUROPATHY. ROSIN IS AN
ALLERGEN.
First Aid
First Aid:EYES: FLUSH WITH COPIOUS QUANTITIES OF WATER. GET IMMEDIATE
MEDICAL ATTENTION. SKIN: WASH WITH SOAP AND WATER. INHAL: REMOVE
FROM EXPOSURE. GET MEDICAL ATTENTION IF EXPERIENCING EFFECTS OF
OVEREXPOSUR E. INGEST: GET IMMEDIATE MEDICAL ATTENTION.
Fire Fighting
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DO NOT USE WATER ON FIRES WHERE MOLTEN
METAL IS PRESENT. HIGH TEMPERATURES MAY PRODUCE HEAVY METAL FUMES,
DUST AND/OR VAPOR.
Accidental Release
Spill Release Procedures:PARTICULATE MATTER SHOULD BE STORED IN DRY
CONTAINERS FOR LATER DISPOSAL. DUST MATERIAL SHOULD BE VACUUMED OR
WET SWEPT. DO NOT USE COMPRESSED AIR OR DRY SWEEPING AS A MEANS OF
CLEANING.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:WASH HANDS WITH SOAP AND WATER AFTER
HANDLING SOLDER. STORE IN DRY AREA. AVOID SKIN CONTACT. AVOID
BREATHING SMOKE DURING SOLDERING.
Other Precautions:NONE KNOWN
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR AS SPECIFIED BY
29 CFR 1910.1025 (F) IF EXPOSURE EXCEEDS PEL.
Ventilation:LOCAL EXHAUST: REMOVE SMOKE FROM BREATHING AREA. MECHANICAL
(GENERAL): ADEQUATE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOG/FULL LGTH FSHLD .
Other Protective Equipment:PERSONAL CLOTHING AND SHOES SHOULD BE
PROTECTED FROM CONTAMINATION. EYE WASH STATION.
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE IN WORK AREAS. WASH
HANDS THOROUGHLY BEFORE EATING OR SMOKING.
Supplemental Safety and Health
HLTH HAZ:A SUSPECTED HUMAN CARCINOGEN BY ACGIH. NOTE:LEAD CAS#7439-92-1
APPEARS ON THE NAVY LISTING OF OCCUP REPRO HAZ. SEEK CONSULTATION
FROM APPROP HEALTH PROFESSIONALS CONCERNING LATEST HAZARD LIST
INFO AND SAFE HANDLING AND EXPOSURE RECOMMENDATIONS .
Chemical Properties
HCC:N1
Melt/Freeze Pt:M.P/F.P Text:361F,183C
Spec Gravity:8 @ 25C(H20=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:GRAY METAL WITH NEUTRAL ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:HIGH TEMPERATURES MAY PRODUCE HEAVY
METAL FUMES, DUST AND/OR VAPORS.
Disposal
Waste Disposal Methods:DISPOSE OF HAZARDOUS WASTES IN ACCORDANCE WITH
LOCAL, STATE AND FEDERAL REGULATIONS. CONSULT A LICENSED HAZARDOUS
WASTE COMPANY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.